{"product_id":"mebay-multifunctional-genset-panel-meter-gv16vs-1-relay-output-2-channel-switch-input","title":"MEBAY Multifunctional Genset Panel Meter GV16VS 1 Relay Output 2-channel Switch Input","description":"\u003cdiv class=\"J_module\"\u003e\n\u003cdiv class=\"detail-decorate-json-renderer-container\"\u003e\n\u003cdiv class=\"magic-14\"\u003e\n\u003cdiv class=\"magic-17\"\u003e\n\u003cdiv class=\"magic-18\"\u003e\n\u003cdiv class=\"magic-19\"\u003e\n\u003cspan\u003eGV16VS is a light weight and low-cost module used for measuring and displaying AC voltage, frequency, current, power, battery voltage, and cumulative operating time. It can replace traditional pointer instruments and achieve multi-purpose use of one meter.\u003c\/span\u003e\n\u003cdiv\u003e\n\u003cspan\u003e\u003cbr\u003eIt has alarm protection functions for over frequency, under frequency, over voltage, under voltage, over current, and over power, which can stop the unit in a timely manner when a fault occurs, effectively protecting the safety of the unit.\u003c\/span\u003e\u003cspan\u003e\u003cspan class=\"magic-16\" style=\"font-family: Arial;\"\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"J_module\"\u003e\n\u003cdiv class=\"ife-detail-decorate-table\"\u003e\n\u003ctable class=\"has-title is-zebra all magic-20\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv class=\"magic-21\"\u003e\n\u003cdiv class=\"magic-22\"\u003e\u003cb\u003eDisplay\u003c\/b\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\" rowspan=\"1\"\u003e\n\u003cdiv class=\"magic-23\"\u003e\n\u003cdiv class=\"magic-22\"\u003e\u003cb\u003eAlarm\u003c\/b\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv class=\"magic-21\"\u003eEngine battery voltage V\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv class=\"magic-26\"\u003eOverfrequency alarm\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv class=\"magic-27\"\u003eBattery undervoltage warning\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv class=\"magic-21\"\u003eGenerator frequency Hz\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv class=\"magic-26\"\u003eUnderfrequency alarm\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv class=\"magic-27\"\u003eLow oil pressure switch alarm\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv class=\"magic-28\"\u003eGenerator voltage V\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv class=\"magic-29\"\u003ePower generation overvoltage alarm\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv class=\"magic-30\"\u003eHigh temperature switch alarm\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv class=\"magic-28\"\u003eGenerator current A\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv class=\"magic-29\"\u003ePower generation undervoltage alarm\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv class=\"magic-30\"\u003eLow fuel level switch alarm\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv class=\"magic-28\"\u003eGenerator active power KW\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv class=\"magic-29\"\u003eOvercurrent alarm\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv class=\"magic-30\"\u003eEmergency stop input alarm\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv class=\"magic-28\"\u003eThe cumulative operating time of the unit is H.\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv class=\"magic-29\"\u003eOverpower alarm\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv class=\"magic-30\"\u003eLow fuel level switch warning\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv class=\"magic-21\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv class=\"magic-26\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv class=\"magic-27\"\u003eLow water level switch alarm\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable class=\"all magic-20\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" rowspan=\"1\"\u003e\n\u003cdiv class=\"magic-41\"\u003e\n\u003cdiv class=\"magic-22\"\u003e\u003cb\u003eSpecification\u003c\/b\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv class=\"magic-43\"\u003e\u003cb\u003eOperation Voltage\u003c\/b\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv class=\"magic-44\"\u003eDC8-36V Continuous\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"2\"\u003e\n\u003cdiv class=\"magic-45\"\u003e\u003cb\u003ePower Consumption\u003c\/b\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv class=\"magic-44\"\u003eStandby: 24V: MAX 1W\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv class=\"magic-47\"\u003eWorking: 24V: MAX1.5W\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv class=\"magic-43\"\u003e\u003cb\u003eAC Voltage Input\u003c\/b\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv class=\"magic-44\"\u003e1P2W(L-Ninput)30VAC-500VAC(L-NorL-L)\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv class=\"magic-46\"\u003e\u003cb\u003eAC current input\u003c\/b\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv class=\"magic-47\"\u003eTransformer secondary input MAX62.5mA\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv class=\"magic-46\"\u003e\u003cb\u003eMAX Accumulating Time\u003c\/b\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv class=\"magic-47\"\u003e99999 hours (minimum save time 36 seconds,minimum\u003cbr\u003edisplay time 6 minutes)\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv class=\"magic-46\"\u003e\u003cb\u003eOutput\u003c\/b\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv class=\"magic-47\"\u003ePassive contact output max DC 3A\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv class=\"magic-46\"\u003e\u003cb\u003eSwitch value input\u003c\/b\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv class=\"magic-47\"\u003eAvailable if connecting with Battery-\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv class=\"magic-46\"\u003e\u003cb\u003eWorking condition\u003c\/b\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv class=\"magic-47\"\u003e-30-70℃\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv class=\"magic-46\"\u003e\u003cb\u003eStorage condition\u003c\/b\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv class=\"magic-47\"\u003e-40-85℃\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv class=\"magic-46\"\u003e\u003cb\u003eInsulation strength\u003c\/b\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv class=\"magic-47\"\u003eApply AC2.2kV voltage between high voltage terminal\u003cbr\u003eand low voltage terminal;The leakage current is not\u003cbr\u003emore than 3mA within 1min.\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv class=\"magic-46\"\u003e\u003cb\u003eOverall dimension\u003c\/b\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv class=\"magic-47\"\u003e83mm×66mm×35mm\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv class=\"magic-46\"\u003e\u003cb\u003ePanel cutout\u003c\/b\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cdiv class=\"magic-47\"\u003e75mm×59mm\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"penny512sm","offers":[{"title":"Default Title","offer_id":42987441651797,"sku":"GV16VS","price":17.5,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0562\/0790\/0757\/files\/01_5bc5a606-5075-4d20-9e8b-2977bf0ac536.jpg?v=1789275210","url":"https:\/\/www.genpartstec.com\/id\/products\/mebay-multifunctional-genset-panel-meter-gv16vs-1-relay-output-2-channel-switch-input","provider":"XFH generator parts","version":"1.0","type":"link"}